نتایج جستجو برای: Breast Phantom

تعداد نتایج: 263836  

ژورنال: پژوهش در پزشکی 2018

Background: Average glandular dose (AGD), entrance skin air kerma (ESAK) and normalized glandular dose (DgN) are the main dosimetric quantities in mammography. Breast tissue composition is one of the factors affecting on DgN values. In this study both homogeneous and heterogeneous breast tissue is assumed and its impact on DgN values are evaluated. Methods: Homogeneous breast phantom with diffe...

Journal: :basic and clinical cancer research 0
narges jooladi tehran university of medical sciences, tehran, iran seyed rabee mahdavi iran university of medical sciences, tehran, iran hasanali nedaei shahid beheshti university of medical sciences, tehran, iran hasan nosrati shahid beheshti university of medical sciences, tehran, iran mansour naderi tehran university of medical sciences, tehran, iran mahbod esfehani tehran university of medical sciences, tehran, iran

background : this study was set to determine the optimal technique of breast cancer with supraclavicular fossa irradiation. methods : three techniques was compared in this study. techniques were two point symmetric (2p-sym), two point asymmetric (2p-asym) and single point (sp). in 2p-sym all of beams were symmetric, in 2p-asym tangential beams were symmetric and supra was asymmetric, in sp all ...

Journal: :iranian journal of radiology 0
lida gholamkar department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran ali asghar mowlavi physics department, hakim sabzevari university, sabzevar, iran; international center for theoretical physics (ictp), associate federation scheme, medical physics field, trieste, italy; physics department, hakim sabzevari university, sabzevar, iran. tel: +98-5144012521 mahdi sadeghi radiation application research school, nuclear science and technology research institute, tehran, iran mitra athari department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran

conclusion by comparing the results, we saw that w/rh anode/filter combination is the best choice in breast mammography imaging because of the lowest delivered dose in comparison with w/ag and rh/al. moreover, breast thickness and g value have significant effects on mgd. objectives the aim of this study was to determine the average absorbed dose of x-ray radiation in the glandular tissue of the...

Mahdi Ghorbanee Mohamad reza Deevband Zeinab Kave

Introduction: Average glandular dose (AGD), entrance skin air kerma (ESAK) and normalized glandular dose (DgN) are the main dosimetric quantities in mammography. In this study, DgN is evaluated in the presence of breast cyst, which is a common disease among women and the influence of size, number and location of the cysts on the DgN is investigated. Materials and Meth...

M Papie R Faghihi S Sina

Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...

Maryam Papie, R Faghihi S Sina

Introduction: Contura is a balloon applicator that used to deliver intra cavity radiation for Partial Breast Irradiation (PBI) treatments. Contura with 4 peripheral lumens surrounding the central, for loading HDR sources from an after loader system can provide an asymmetric dose distribution and gives a more flexible shape of dose than earlier balloon applicators such as Mammo...

2016
Jacob T. Chadwell Rebekah H. Conley Jarrod A. Collins Ingrid M. Meszoely Michael I. Miga

The purpose of this work is to develop an anatomically and mechanically representative breast phantom for the validation of breast conserving surgical therapies, specifically, in this case, image guided surgeries. Using three patients scheduled for lumpectomy and four healthy volunteers in mock surgical presentations, the magnitude, direction, and location of breast deformations was analyzed. A...

2012
Claudia C. Brunner Raymond J. Acciavatti Predrag R. Bakic Andrew D. A. Maidment Mark B. Williams Richard Kaczmarek Kish Chakrabarti

We investigated the appropriateness of four different mammography phantoms for image quality evaluation in Digital Breast Tomosynthesis (DBT). We tested the CIRS BR3D phantom, the ACR Prototype FFDM Accreditation Phantom, the Penn anthropomorphic breast phantom and the Quart mam/digi EPQC phantom. This work discusses the advantages and shortcomings of each phantom and concludes that none of the...

Journal: :Medical physics 2011
Ann-Katherine Carton Predrag Bakic Christer Ullberg Helen Derand Andrew D A Maidment

PURPOSE Develop a technique to fabricate a 3D anthropomorphic breast phantom with known ground truth for image quality assessment of 2D and 3D breast x-ray imaging systems. METHODS The phantom design is based on an existing computer model that can generate breast voxel phantoms of varying composition, size, and shape. The physical phantom is produced in two steps. First, the portion of the vo...

2009
M. Heisen B. Peng A. M. Wood D. Mustafi J. Buurman G. M. Newstead G. S. Karczmar

Introduction: The routine use of a calibration phantom that fits easily into a breast coil could provide the basis for standardization and patient-specific calibration of breast MRI. Here, we use a phantom to correct the variable flip angles in a T1 measurement. This increases the accuracy of T1 and contrast media concentration measurements obtained with a clinically employed T1-weighted dynami...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید